Imagine a robot lifting a wet glass. The glass slips, the controller compensates, and the robot places it successfully. This is an illustrative scenario, not a reported Avala experiment.
How should the recording be labeled? A final success label describes the destination, but leaves out the slip and recovery. Those events may matter for selecting training sequences, diagnosing failures, or evaluating a revised controller. The right annotation depends on the question the team wants to answer and the signals it actually recorded.
The problem is not that manipulation has no taxonomies. It is that a useful label needs an operational definition, supporting evidence, and a documented relationship to other schemas. A shared field name alone does not supply those things.
Build on existing primitives
The GRASP taxonomy synthesizes earlier classifications of human grasp types. It is a useful reference, not a universal description of every robot gripper or manipulation task. A team adapting human grasp categories to a parallel gripper must explain the mapping and where it does not apply.
Likewise, RLDS defines a structure for sequences of steps and allows user-defined metadata. Its documentation includes observations, actions, rewards, and episode metadata; a quality field is not inherently excluded by the format. In RLDS terminology an episode contains steps. Here, a recorded sequence is the unit whose boundaries and annotations need to be specified.
A container can hold an annotation without defining what it means. Two datasets may both include a success field while using different completion criteria. One may call a recovered grasp successful; another may reject any slip. Combining those labels requires a mapping or an explicit distinction, not just matching their column names.
Five annotation layers to define
These are useful scoping questions, not a requirement that every dataset contain every layer.
Task phases. Define observable start and end conditions for approach, contact, lift, transport, and placement where they matter to the task. Include examples at ambiguous boundaries. If intent is inferred rather than recorded, retain that distinction.
Grasp configuration. Specify the embodiment and the contact configuration that the label describes. Reuse a published taxonomy where it fits, and document extensions. A human pinch label does not automatically describe the action space of a robot hand.
Contact and slip events. State what evidence establishes an event: visible relative motion, a tactile signal, an instrumented measurement, or a reviewer's estimate. Occlusion and insufficient temporal resolution may make an event indeterminate. Preserve that state rather than forcing a confident label.
Force and torque signals. Where measured signals exist, retain the sensor, units, coordinate frame, calibration reference, and timing. Commanded force and measured force are different quantities. Do not infer a numerical force from a video label or publish a universal safe threshold for an object category.
Outcome and recovery. Separate final completion from intermediate events. Record an observed slip or collision before assigning a cause. A dropped object could involve perception, planning, control, calibration, or several interacting factors; a label alone does not diagnose the subsystem.
For the wet-glass example, a useful record might distinguish the following. This is an illustrative review worksheet, not an Avala export schema or a measured result:
| Question | What the record should establish |
|---|---|
| Was placement completed? | The task-specific completion rule and the evidence used to assess it |
| Did the glass slip? | The event interval, observation source, and uncertainty |
| Was there a recovery? | The subsequent action or intervention and its relationship to the event |
| Was force recorded? | Measured or commanded signal, units, calibration, or an explicit missing state |
| What caused the event? | A separate diagnostic hypothesis, with supporting evidence or an unresolved status |
Put events on a documented timebase
A label attached to the wrong observation can change the meaning of a sequence. The acceptable timing error depends on the sensor rates, motion, event duration, and downstream task. There is no single millisecond threshold that makes every manipulation label valid or invalid.
Document whether timestamps describe acquisition, command issue, or receipt. Record clock synchronization, estimated offsets, dropped samples, and any interpolation or resampling. Preserve the original timestamps alongside derived alignment so another team can inspect the transformation.
For an event between two camera frames, an interval may be more honest than an exact instant. A higher-rate tactile stream can provide additional timing evidence, but only when its clock relationship to the video is known. Do not manufacture precision by copying one frame index across unrelated streams.
Separate measurable outcomes from preferences
Some outcomes can be measured under a defined protocol: whether an object reached a target, elapsed time, or a recorded force limit violation. Other judgments depend on the program's priorities. A fast motion may be desirable in one setting and unacceptable around a fragile object in another.
Write those priorities into the rubric before scoring the data. Define the observation window, permitted interventions, completion conditions, and handling of uncertain cases. Avoid treating a cautious-looking motion as safer without evidence about the actual contact and result.
Use representative examples to calibrate reviewers. Track agreement by label type and review disagreements rather than reducing all quality to one score. When the rubric changes, version it and preserve which definition produced each historical judgment.
Evaluate automation against the label it produces
Automation can propose phases, descriptions, and event candidates. Its suitability is an empirical question for the task and available signals. Neither a model-generated label nor a human judgment should become ground truth solely because of who produced it.
Evaluate proposals against an appropriate reference set. Inspect missed events, false detections, boundary errors, and performance under occlusion or missing channels. Decide which cases need adjudication and retain the source of each accepted label.
Video may support an estimate of contact or slip, but an estimate should not silently become a force measurement. A model with access to tactile data has different evidence from one that sees only images. Record those inputs and the model version so the result can be interpreted and reproduced.
Specify compatibility before combining datasets
Start with a narrow task and a small set of labels that answer a real training or evaluation question. For each label, publish a definition, applicable embodiments, units where relevant, timing convention, evidence requirements, and unknown states. Include positive, negative, and ambiguous examples.
Then test the mapping between datasets. Preserve source labels and document whether a conversion is exact, many-to-one, or lossy. If one source combines slip and drop while another separates them, the merged field must not pretend to retain a distinction the first source never recorded.
Schema compatibility is only one part of reuse. Rights, sensor calibration, action representations, environment differences, and train/evaluation separation still matter. A successful file conversion is not proof that combining the datasets improves a policy.
Start with the next recording you need to understand
For the wet-glass sequence, preserve the final outcome, the slip interval, the recovery, and the evidence behind each judgment. Leave force and causal diagnosis unknown when the recording cannot establish them. That is more useful than a detailed schema filled with guesses.
Agree on this contract before expanding collection or annotation. Validate it on a representative slice, review the ambiguous cases, and check that the receiving training or evaluation workflow can use the output as intended.
Explore Avala's labeling capabilities or scope a managed labeling program around your sensors, taxonomy, and acceptance criteria. The aim is a dataset another team can interpret and test, with its limits intact.